SENSOR : Light Weight Vane type

RANGE : 0 to 9,9 meters/sec

RESOLUTION : 0,1 meters/sec

OUTPUT : 3 digit LCD

ACCURACY : ± 2%

POWER : NiCd Battery Pack Automatic Charger and Carrying Case Provided

SENSOR : (a) 3 cup Anemometer,(b) Wind Vane

DATA LOGGING : Unit Features : Sampling Time : 2-5 Seconds

STATISTICS OF WIND DATA :Wind Rose Data for eight points of Compass. Data Storage in Memory Module.

SENSOR : Moulded Plastic 3 Cup Assembly /Stainless Steel Cup Assembly /Optical Sensing

RANGE : 0 à 65 mèters/sec

CONNECTOR : 3 pin MS

OUTPUT : TTL Level Pulses

ACCURACY : more than ą ± 2%

HOUSING : SS 316/ Brass/ Aluminium

POWER : 5 VDC

RANGE :0 ą 99 kmph or meter/sec

RESOLUTION : 0,1 kmph/ 0,1 knot/ 0,1 m/sec

OUTPUT : Direct reading on LCD display

ACCURACY :± 3% ou 0,5 km/h

SAMPLING TIME : 2 seconds

POWER :NiCd Battery PAck Automatic Charger and Carrying Case Provided

SENSOR:(a) Anemometer (b) Wind Vane

INPUT : Wind speed, Wind direction

OUTPUT : Two three and half digit LCD's indicating Wind Speed and Wind Direction

SENSOR:Float Potentiometer combination in stilling well

OUTPUT : Resistance proportional to level

ACCURACY : Better than 1 mm

Available in Copper and SS

 

SENSOR:Solid State Humidity Sensor

RANGE :3 to 99%

RESOLUTION : 0,1 %

OUTPUT :3 digit LCD

ACCURACY : ± 3%

STEM :SS 316 or Brass

SENSOR: Stainless Steel Capsule and Straingauge with built-in lineariser

RANGE :850 - 1050 mb (Heeta Pascal)

RESOLUTION : 0,1 mb (Heeta Pascal)

OUTPUT : 1 - 4 volts (0 - 5 volts optional)

ACCURACY : 0,3 mb

Other outputs can be provided on request.*Other ranges can be provided

SENSOR: Standard Platinum RTD Element (PT 1000)

RANGE :-40° to +60°C

RESOLUTION : 0,1 °C

ACCURACY : ± 0,2°C

STEM :SS 316

SUNSHINE CARDS: Summer(Long curve)/Winter(Short curve)/Equinoxial(Straight)

RECORDING CHARTS:

    • Daily raingauge charts
    • Thermograph charts
    • Barograph charts

ANALOG CONVERTOR : 12 bits

INPUT VOLTAGE : 0 to 1 volt

SAMPLING TIME : 5 seconds

DATA STORAGE : On RAM (Random Access Memory)

DATA STORAGE INTERVAL : Normally 1 hour, can be made programmable from 1 Min to 1 Hour steps through keyboard.

DATA STORAGE CAPACITY :15 to 20 days (hourly averages)

POWER REQUIREMENT : 12 VDC, 200mW average Cosumption

NUNMBER OF CHANNELS :8 to 32 (Optional)

SENSOR: Vane Coupled to Linear Endless Potentiometers

RANGE : 0 to 357°

RESOLUTION :

OUTPUT : 0 to 5k resistance

ACCURACY : ±3°

HOUSING : SS 316 / Brass / Aluminium

CONNECTOR : 3 pin MS

Direct reading Mechanical Vane, Direct reading Scale 5° resolution, Built-in Compass to find North at any place.

Hand Held Anemometer and Portable Wind Vane are available as a combination in a moulded carrying case with battery charger and spare Cup for Anemometer.

RAINGAUGE : Tipping Bucket Raingauge

SENSOR : Magnet Reed Switch

RESOLUTION : 0,2mm / 0,5mm

CAPACITY : Unlimited

Available in FRP / SS 316

SENSOR : Collector Area of 100 sq.cm. FRP Shell

MAX RANGE : 300mm/h

MECHANISM : Drop forming system made of SS

SAMPLING TIME : 10 / 60 sec switch selectable

The data can be continuously printed on a standard parallel printer or Stored in a memory module for later transfer to computer

SENSOR : Two blackened surfaces with Copper Constantan Thermopile

SENSITIVITY : 40 Micro Volts / Watt / Sq.meter

SPECTRAL RANGE : 0,3 to 60 microns

SENSOR : Seventy element Thermopile

OUTPUT : > 10 Micro Volts / Watt / Sq. Meter

SPECTRAL RANGE :0,3 to 3 microns

TIME CONSTANT :< 20 seconds

SENSOR : Standard Platinum RTD (PT 1000)

RANGE :-40° to +60° C

RESOLUTION : 0,1 °C

OUTPUT : Variation of Resistance

ACCURACY : ± 0,2°C

STEM : SS 316/ Brass / Aluminium

35. rue Scheurer Kestner 42000 SAINT ETIENNE -Tel. : + 334 77 92 20 00- Fax : + 334 77 74 71 09